The details
Product details
OverviewProduct details and key features
The Buck Stove ZCBBXL brings an oak-log flame display to a built-in fireplace installation. This specific package is configured for liquid propane and includes the log set, blower and on/off remote. A decorative mantel or surround is not included.
What the price includes
NV 42ZCBBXL-OLP firebox with propane Oak Embervision gas logs, on/off remote and blower.
Complete your installation
Have a qualified installer confirm room suitability, combustion air, clearances, gas supply and local permission for a vent-free appliance before ordering. This is not a natural-gas version. Framing, non-combustible facing, mantel and installation are separate.
Specifications
- Fuel: Liquid propane
- Format: 42-inch zero-clearance vent-free fireplace
- Log style: Oak
- Controls: On/off remote; millivolt valve
- Blower: Included
- Ignition: Piezo
- Safety control: Oxygen-depletion sensor
Availability and delivery
Contact us to confirm dispatch timing for your selected model and any required components. Transit time is additional. The availability indicator applies to the selected SKU, not to separately ordered installation components.
Ask us to review your project and quote the required components.
Product documents
SpecificationsDimensions, fuel and installation requirements
| Fuel | Liquid propane |
|---|---|
| Format | 42-inch zero-clearance vent-free fireplace |
| Log style | Oak |
| Controls | On/off remote; millivolt valve |
| Blower | Included |
| Ignition | Piezo |
| Safety control | Oxygen-depletion sensor |
Shipping & returnsDelivery and returns
Contact us to confirm dispatch timing for your selected model and any required components. Transit time is additional.
Review our shipping policy and return policy before ordering.
WarrantyProduct coverage
Warranty coverage and terms vary by manufacturer and component. Refer to the manufacturer documents for this model.
Contact our team with your order number if you need help with a warranty claim.
In real homes
Reviews from our customers
No reviews on this product yet. Read customer reviews of other ExceptionalFire purchases below.
Reviews are taking a little longer to load. You can read them directly on Loox.
This is a vent-free model — check your local code first
Vent-free fireplaces are excellent in the right home and not permitted in others. It takes about ten minutes to confirm, and it is much cheaper to do it now than after installation.
What “vent-free” means
This unit burns gas with no chimney or flue, so all combustion products stay in the room. It is built and listed to ANSI Z21.11.2 and carries an oxygen-depletion sensor (ODS) that shuts off the gas if the oxygen level in the room falls.
Model fuel-gas code caps a vent-free heater at 40,000 BTU/h, limits the combined input of all unvented appliances to 20 BTU/h per cubic foot of room volume, and does not allow it to be the sole source of heat for a home. Your room size genuinely matters here.
Where it is restricted
- California — state law prohibits the sale of unvented heaters designed for use inside a dwelling. Vented decorative gas logs are expressly exempt.
- Minnesota — unvented room heaters and unvented decorative appliances may not be installed in any dwelling or occupancy. No exceptions in the rule.
- Wisconsin — permanently installed gas-fired unvented heating appliances may not be installed; unvented space heaters are separately prohibited in one- and two-family dwellings.
- Massachusetts — allowed only with a permit from the head of the fire department, inspection by the fire department and the gas inspector, a 40,000 BTU cap per room, a CO detector in the room, and never as the primary heat source.
- Manufactured (HUD-code) homes, anywhere in the US — federal rule requires fuel-burning heating appliances to be vented to the outside.
How to confirm for your address
Your city or county can be stricter than your state, and these rules change. That is why we do not publish a state-by-state map — the decision is made locally, by a person, not nationally. Call in this order:
- Local building department. Ask: is a vent-free gas fireplace permitted here, and do I need a permit? They know the adopted code edition and any local amendments.
- Fire department or fire marshal. Required in Massachusetts before the unit may be operated, and commonly the deciding authority elsewhere.
- Local or state gas / plumbing inspector. This is who signs off on the final inspection.
- Your gas utility. Some will not set or upgrade a meter for an unvented appliance.
We cannot give legal advice and we cannot approve an installation — only your local authority can. If you tell us what they say, we will help you match the right unit to it.
Based on primary sources: Cal. Health & Safety Code §19881 · Minn. R. 1346.5621 & 1346.5602 · Wis. Admin. Code SPS 365.0621 & SPS 323.04(2)(b) · M.G.L. c.148 §25A with 248 CMR 5.10 and 527 CMR 1.05 · 24 CFR 3280.707(b) · IFGC §621 and §303.3. Last reviewed August 2026.






















